Casio QX-973 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Nein Casio QX-973 herunter. Casio QX-973 User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
5052Ver2.00-EN.fm/2
Schneider Electric
The XBK counters associated with detection products (photo-electric detectors, inductive sensors, limit switches) or
dialogue products (pushbuttons, selector switches, etc) can be used to provide a complementary function of the control
system : counting.
XBK counters complement the Magelis range of display units and operator dialogue terminals by offering simple display
and entry functions. They are fully compatible with labelled Telemecanique detection and man-machine dialogue
products.
The offer is divided between two technologies : electromechanics and electronics.
Electromechanics is used for slow counting applications, of around several tens of hertz, whereas electronics is adapted
to counting frequencies of around a kilohertz.
These two technologies can be subdivided into three distinct product families :
- totalising counters,
- predetermining counters,
- totalising timers.
These three families offer products with varying characteristics :
- display capacity,
- type and number of outputs,
- types of input,
- reset to zero option,
- adding, subtracting, bidirectional or programmable counting mode,
- display in hundredths of an hour (hour counters).
This enables the products to be more application-specific.
Introduction
Functions
Technology
Counters
Totalising counters, predetermining counters and totalising timers
General
Characteristics :
pages
35053/2
and
35053/3
References :
pages
35054/2
and
35054/3
Dimensions :
pages
35055/2
and
35055/3
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - Counters

5052Ver2.00-EN.fm/2Schneider Electric The XBK counters associated with detection products (photo-electric detectors, inductive sensors, li

Seite 2

35056_Ver2.01-EN.fm/3Schneider Electric (1) Possible with a 680 Ω resistor fitted in parallel(2) It is preferable to use contacts designed for low cur

Seite 3

14100_Ver4.00-EN.fm/2Schneider Electric“Zelio Logic” smart relay The “Zelio Logic” smart relay is designed for use in small automated systems.It is s

Seite 4

14100_Ver4.00-EN.fm/3Schneider Electric 1314SR22 21A1A2– KM1 (1)A1A2AR2324KM11314BP 1I1Q1– KM1I2BP 1ARI1Q1– KM1I2BP 1ARA1A2A1A2

Seite 5

14100_Ver4.00-EN.fm/4Schneider Electric “Zelio Logic” smart relayFunctions FunctionsThe Zelio Logic smart relay comprises- 8

Seite 6

14100_Ver4.00-EN.fm/5Schneider Electric Functions (continued)“Zelio Logic” smart relay Modes Parameter entry mode This

Seite 7

14100_Ver4.00-EN.fm/6Schneider Electric“Zelio Logic” smart relay “Zelio Soft” software enables :- inputting of control schemes,- detection of any pro

Seite 8

14100_Ver4.00-EN.fm/7Schneider Electric“Zelio Logic” smart relay The Pocket PC allows : - full entry of control schemes, including the mes

Seite 9

14100_Ver4.00-EN.fm/8Schneider Electric“Zelio Logic” smart relay Environmental characteristics Approvals UL,

Seite 10

14100_Ver4.00-EN.fm/9Schneider Electric“Zelio Logic” smart relay Discrete $ 24 V input characteristicsSmart rel

Seite 11 - “Zelio Logic” smart relay

14100_Ver4.00-EN.fm/10Schneider Electric“Zelio Logic” smart relay Relay output characteristics (screw terminal conn

Seite 12

35052Ver2.00-EN.fm/Schneider Electric Totalising countersPredetermining countersTotalising timer

Seite 13

14100_Ver4.00-EN.fm/11Schneider Electric 0 1,5120,50,00,51,01,52,02,53,024 V48 V0,1 0,3 0,5 0,7 0,9 10,2 0,4 0,6 0,80,01,41,21,00,80,60,40,2L

Seite 14

14100_Ver4.00-EN.fm/12Schneider Electric“Zelio Logic” smart relay (1) Counting or elapsed time values saved in the event of a power fai

Seite 15

14100_Ver4.00-EN.fm/13Schneider Electric“Zelio Logic” smart relay Power supply (1)InputvoltageNominalou

Seite 16

14100_Ver4.00-EN.fm/14Schneider Electric“Zelio Logic” smart relay (1) 1 A quick-blow fuse or circuit-breaker.DimensionsSmart relays SR1-SR1-

Seite 17

14100_Ver4.00-EN.fm/15Schneider Electric“Zelio Logic” smart relay (1) 1A quick-blow fuse or circuit-breaker.(2) 16A fuse or circuit-breaker (B16).(3)

Seite 18

5053Ver3.00-EN.fm/2Schneider ElectricCountersTotalising counters, predetermining counters and totalising timers Type of device XBK

Seite 19

35053Ver3.00-EN.fm/Schneider ElectricCountersTotalising counters, predetermining counters and totalising timers Type of device XBK-P5

Seite 20

35054_Ver3.01-EN.fm/2Schneider Electric ReferencesWith mechanical display With mechanical display (max. display capacity : 99999.99 h)

Seite 21

35054_Ver3.01-EN.fm/3Schneider Electric CountersTotalising counters, predetermining counters and totalising timers Subtracting pr

Seite 22

5055_Ver3.00-EN.fm/2Schneider Electric 64,275e41,53138,52745+0,622+0,3484830203240e60756388,5102,2

Seite 23

35055_Ver3.00-EN.fm/3Schneider Electric -/+-/+23–+131102111131102–+132–+161A1A213314174–+ PNPNPNResetCount0 VKeylock3214–+ResetCount0 VKeylo

Seite 24

35056_Ver2.01-EN.fm/2Schneider Electric (1) Possible if volt drop < 2.4 V (otherwise, boost the supply)(2) Incompatible with sensors or photocells

Kommentare zu diesen Handbüchern

Keine Kommentare