20021201
4. Move the trace pointer to the end point of the range for which you want to perform Fourier
series expansion, and then press w.
• This displays a dialog box for specifying the lists where you want to store the time data
and the sampled data.
• The initial default lists are List 1 for the time and List 2 for sample data. To change to
another list (List 1 to List 20), use the up and down cursor keys to move the highlighting
to the list you want to change, and then input the applicable list number.
5. Press w.
• This saves the time and sampled values as list data, and displays a dialog box for
inputting the degree of the Fourier series.
/
6. Input a value in the range of 1 to 10, and then press w.
• After a short while, the graph function list appears with the calculation result.
11-6
Graph Analysis Tool Graph Screen Operations
7. Pressing 6(DRAW) here graphs the function.
• This lets you compare the expanded function graph and the original graph to see if they
are the same.