Data communications capabilities let you transfer data between two CASIO
PV Units, between a PV Unit and a BN-10/BN-20 Unit, or between a PV
Unit and a BN-10A/BN-20A/BN-40A Unit. You can also receive data from a
CASIO SF, CSF, or NX Series Unit, and communicate with a personal
computer using PC sync for Windows.
See the manual that comes with PC sync for Windows for details on
connecting to a computer and setting up for communication.
Chapter
10
Data Communication
Using the Cradle............................................................................ 122
To connect the PV Unit to the cradle ........................................................ 122
To detach the PV Unit from the cradle ..................................................... 123
Data Communications Between Two PV Units .......................... 123
To connect two PV Units .......................................................................... 123
To send data from the host unit to the terminal unit ................................. 124
To receive data from the terminal unit on the host unit ............................ 126
Data Communications Between a PV Unit and a BN Unit ....... 129
To connect a PV Unit to a BN Unit .......................................................... 129
To send data from the PV Unit to the BN Unit ........................................ 130
To receive data from the BN Unit on the PV Unit.................................... 132
Receiving Data From an SF/CSF/NX Series Unit ...................... 134
To connect a PV Unit and an SF/CSF/NX Series Unit............................. 134
To make communication parameter settings ............................................ 135
To receive data from an SF/CSF/NX Series Unit ..................................... 137
10
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - Data Communication

121Data communications capabilities let you transfer data between two CASIOPV Units, between a PV Unit and a BN-10/BN-20 Unit, or between a PVUnit and

Seite 2 - Using the Cradle

130To send data from the PV Unit to the BN Unit1. After connecting the two units, turn on the PV Unit.• BN Unit power should still be off at this time

Seite 3

131Chapter 10 Data Communication6. Tap Set.7. Tap the check boxes to specify the data you want to send (checked) andthe data you do not want to send (

Seite 4 - Host unit Terminal unit

132• The following shows the relationship between data when sent from thePV Unit to a BN Unit.To receive data from the BN Unit on the PV Unit1. Perfor

Seite 5

133Chapter 10 Data Communication3. Tap Set.4. Tap the check boxes next to specify the data you want to receive (checked)and the data you do not want t

Seite 6

134• Transferring data from the PV-200A/PV-250X/PV-400A/PV-450X to theBN Unit causes all euro symbols to be replaced by spaces.• The following shows t

Seite 7

135Chapter 10 Data Communication4. Use an optional SB-90 9-9 pin connector to connect the PV Unit cradleto the other unit’s cable.To make communicatio

Seite 8

1363. Tap the Menu Bar icon to display the menu bar, and then tap System –Data communication.4. Tap the button next to SF/CSF/NX.5. Press the button n

Seite 9

137Chapter 10 Data CommunicationTo receive data from an SF/CSF/NX Series Unit1. After connecting the two units, turn on the PV Unit.2. Display the lis

Seite 10

138Notes• Data communication can be interrupted at any time by tapping Esc.This causes the message Stopped! to appear on the display of the PVUnit.• T

Seite 11 - Chapter 10 Data Communication

122Using the CradleThe PV Unit comes with a cradle that helps to make data communications quickerand easier. The following procedures describe how to

Seite 12

123Chapter 10 Data CommunicationTo detach the PV Unit from the cradle1. Turn off PV Unit power.2. Lift up on the PV Unit while holding down the cradle

Seite 13

1243. Use an optional SB-90 9-9 pin connector to connect the two cradles toeach other.• All data communication settings must be made on only one of th

Seite 14

125Chapter 10 Data Communication3. Tap the Menu Bar icon to display the menu bar, and then tap System –Data communication.4. Tap the button next to Po

Seite 15

1268. After everything is the way you want it, tap Set.9. Turn on the power of the terminal unit and then press the Start buttonon its cradle to start

Seite 16

127Chapter 10 Data Communication3. Tap Set.4. Tap the check boxes to specify the data you want to receive (checked)and the data you do not want to rec

Seite 17

128Notes• The above procedures can be used to send or receive all data in specificmodes only. You cannot send or receive individual data items.• Data

Seite 18

129Chapter 10 Data CommunicationData Communications Between a PV Unit anda BN UnitThis section describes how to set up and communicate between a PV Un