Casio Fx-96SG Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Wasserpumpen Casio Fx-96SG herunter. Casio Fx-96SG User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User’s Guide

Efx-96SG PLUSUser’s GuideCASIO Worldwide Education Website http://edu.casio.comCASIO EDUCATIONAL FORUM http://edu.casio.com/forum/

Seite 2 - Contents

E-9allowable height of a calculation formula is two display screens (31 dots × 2). Further input will become impossible if the height of the calcula

Seite 3 - Handling Precautions

E-10function and then input it. Be sure always to use the insert mode if Linear Display is selected. To clear all of the calculation you are inputt

Seite 4 - Key Markings

E-11Percent Calculations Inputting a value and pressing 1((%) causes the input value to become a percent. 150 × 20% = 30 150 * 20 1((%) =

Seite 5 - Reading the Display

E-12 Transform the value 123 to engineering notation, shifting the decimal point to the left. 123 = 123 1W( ← ) 0.123×10 3

Seite 6

E-13 Variables (A, B, C, D, E, F, X, Y) Your calculator has eight preset variables named A, B, C, D, E, F, X, and Y. You can assign values to variab

Seite 7 - Basic Input Rules

E-14°, r, g : These functions specify the angle unit. ° specifies degrees, r radians, and g grads. Input a function from the menu that appears when yo

Seite 8

E-15 Examples sin 30°= 0.5 bv s 30 )= 0.5 sin −1 0.5 = 30° bv 1s(sin −1 ) 0.5 )= 30 sinh 1 = 1.175201194 wb(sinh)

Seite 9

E-16 To obtain three random three-digit integers 1000 1.(Ran#) = 459 = 48 = 117 (Results shown here are for illustrati

Seite 10 - MathMath

E-17 Inputting Data Use the Stat Editor to input data. Perform the following key operation to display the Stat Editor: 11(STAT) 2(Data). The Stat

Seite 11 - Basic Calculations

E-18 Regression Coefficients: A, B, Correlation Coefficient: r , Estimated Values: m, n11(STAT) 5(Reg) 1 to 5 Regression Coeffici

Seite 12 - Using Engineering Notation

ContentsImportant Information ...2Sample Operations ...

Seite 13

E-19 A11(STAT) 5(Reg) 2(B) = Results: Linear Regression Correlation Coefficient: 0.923 Logarithmic Regression Correlat

Seite 14 - Function Calculations

E-20 11(STAT)5(Distr)1(P()G)= Results: Normalized variate ('t): –0.762 P(t): 0.223Equation Calculations (EQN) You can use t

Seite 15 - Rectangular

E-21 EQN Mode Calculation Examples x + 2 y = 3, 2 x + 3 y = 4 N3(EQN) 1(a n X + b n Y = c n )

Seite 16 - Examples

E-22 l(BIN) 11 + 1 = Continuing from above, switch to the hexadecimal mode and calculate 1F16 + 116 A6(HEX) 1 t(F)+ 1 = Continuing from ab

Seite 17

E-23Converting a Calculation Result to another Type of ValueYou can use any one of the following key operations to convert the currently displayed cal

Seite 18 - Inputting Data

E-24 Calculation Range and Precision Calculation Range ± 1 × 10 –99 to ± 9.999999999 × 10 99 or 0 Number of Digits for Internal Calculati

Seite 19 - STATSTAT

E-25 Pol( x , y ) | x | , | y |  9.999999999 × 10 99 x2 + y2  9.999999999 × 10 99 Rec( r ,  ) 0  r  9.99

Seite 20

E-26 e (or d) d 1 = Clearing the Error Message While an error message is displayed, press A to return to the calculation screen

Seite 21 - Equation Calculations (EQN)

E-27 3. If the above steps do not correct your problem, press the O key. This will cause the calculator to perform a routine that checks whether cal

Seite 22 - Base-n Calculations (BASE-N)

E-28k What is the difference between Ans memory, independent memory, and variable memory? Each of these types of memory acts like “containers”

Seite 23

E-2 Important Information • The displays and illustrations (such as key markings) shown in this User’s Guide are for illustrative purposes only, and

Seite 24

Manufacturer:CASIO COMPUTER CO., LTD.6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, JapanResponsible within the European Union:CASIO EUROPE GmbHC

Seite 25

CASIO COMPUTER CO., LTD.6-2, Hon-machi 1-chomeShibuya-ku, Tokyo 151-8543, JapanSA1209-B© 2012 CASIO COMPUTER CO., LTD.

Seite 26

E-3 • Never try to take the calculator apart. • Use a soft, dry cloth to clean the exterior of the calculator. • Whenever discarding the cal

Seite 27

E-4Reading the Display The display of the calculator shows expressions you input, calculation results, and various indicators. Input expression Indi

Seite 28 - Frequently Asked Questions

E-5 Important: For some type of calculation that takes a long time to execute, the display may show only the above indicators (without any value) w

Seite 29

E-63Deg 4Rad 5Gra Specifies degrees, radians or grads as the angle unit for value input and calculation result display.Note: In this manual, the

Seite 30 - Manufacturer:

E-7 4 × sin30 × (30 + 10 × 3) = 120 4 *s 30 )*( 30 + 10 * 3 )= * 1 * 2 * 3 * 1 Input of the closing parenthesis is re

Seite 31 - 6-2, Hon-machi 1-chome

E-8Note: • If the calculation becomes longer than the screen width during input, the screen will scroll automatically to the right and the ] indicat