ChapterAll of the explanations provided here assume that you are already familiarwith the operating precautions, terminology, and operational procedur
(4) Measurement Time Recording Method (Rec Time)• 1(None) ... No time recorded.• 2(Abs) ... Absolute time in seconds from start of sampling•
2. Use the function key operations described below to change Trigger Setup settings.•To change the setting of an item, first use the f and c cursor ke
OptionUse the Option Setup screen to make View Window settings, to specify the channel for real-time sampling, and to make filter settings.• To change
(3) Real-time Sampling Channel (Use CH)• 1(CH1) ... Channel 1• 2(CH2) ... Channel 2• 3(CH3) ... Channel 3• 4(SONIC) ... Sonic channel•
• To configure a custom probe starting from the Advanced Setup menu1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display theAdvance
• To configure a custom probe starting from the Channel parameter setting screen1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to displ
u To use the MULTIMETER ModeYou can use the Channel parameter settings of Advanced Setup to configure a channel sothat EA-100 MULTIMETER Mode sampling
3-1Setup Memory3. Setup MemoryYou can use setup memory to save EA-100 setups you create using Setup Wizard orAdvanced Setup in calculator memory for l
2. Press 2(SAVE).• This displays the screen for inputting the setup name.3-2Setup Memory3. Press w and then input a memory number (1 to 99).• This sav
u To recall a setup and use it for samplingBe sure to perform the following steps before starting sampling with the EA-100.1. Connect the calculator t
1-1E-CON Overview1. E-CON Overview• From the Main Menu, select E-CON to enter the E-CON Mode.• The E-CON provides the functions listed below for simpl
u To delete setup data1. On the E-CON main menu, press 2(MEM) to display the setup memory list.2. Use the f and c cursor keys to highlight the name of
4. Program ConverterProgram Converter converts an EA-100 setup you created using Setup Wizard or AdvancedSetup to a program that can run on the calcul
3. Press w.• This starts conversion of the setup data to a program.• The message “Complete!” appears when conversion is complete.u To convert setup da
5. Starting a Sampling OperationThe section describes how to use a setup created using the E-CON Mode to start an EA-100sampling operation.k Before ge
u To start sampling1. Start the sampling operation by performing one of the function key operations describedbelow.• If the final Setup Wizard screen
5-3Starting a Sampling Operation Real-Time Normal Sampling Normal Sampling Trigger Start [TRIGGER] Key PhotogateSampling TypeSamplingPress [EXE] to s
2. EA-100 SetupYou can use the E-CON Mode to set up the EA-100 for sampling and then start samplingimmediately or save the setup in calculator memory.
u To create an EA-100 setup using Setup WizardBefore getting started...• Before starting the procedure below, make sure you first decide if you want t
6. After you complete step 5, a screen for setting the number of samples appears on thedisplay.• Use the number keys to input the number of samples, a
k Creating an EA-100 Setup Using Advanced SetupAdvanced Setup provides you with total control over a number of parameters that you canadjust to create
•You can return the settings on the above setup screens (b through e) using theprocedure described under “To return setup parameters to their initial
• To change Channel parameter settings1. While the Advanced Setup menu is on the display, press b(Channel).• This displays the Channel parameter setti
SampleSelecting this parameter displays a screen for making real-time settings, and for specifyingthe sampling interval, number of samples, measuremen