— 7 —
Output
Set Voltmeter
R62
3) Equipment connection/Procedure
Vop voltage setting
Input
Connection
Input
Point
Input
Signal
Adjust
Output
Connection
Output
Point
Adjust for
VR1 Voltmeter R62 Adjust for 4.40 ~ 4.46 V read-
ing on voltmeter under the
temparature 20 ~ 25 °C.
Make fine adjustment accord-
ing to the following instruc-
tion.
Watching the LCD at a 37° angle to the horizontal, adjust Vop
voltage so that unenergized segments are seen dimly.
ADJUSTMENT
MAIN PCB
1) Items to be adjusted:
2) Adjustment and Test Point Locations
(TOP VIEW)
Item
Measuring Instrument
Vop voltage setting Voltmeter
37°
LCD
Eye
(BOTTOM VIEW)
Test point
VR1